Schego diaphragm pumps have been used for a wide range of applications for over 60 years. Originally designed as aquarium pumps subject to the hardest use 24 hours a day, 365 days a year, the spectrum of applications is increasing continuously.
Today, our pumps are used in plant monitoring, measuring and control technology, medical equipment, laboratories, level control systems, for foaming caustic baths and a host of applications involving ventilation, air or gas transportation or where a vacuum is needed.
Schego diaphragm pumps work with electro-magnetic power and are designed for continuous operation. They are made as pressure and transport pumps for gaseous materials. The pumps for transporting air have an outlet piece; air is sucked in from the surrounding area. Pumps for transporting gas have inlet and outlet pieces (E/A model). We also offer vacuum pumps.
Normal performance is shown on the diagram. Within the framework of special series, we can also make individual versions to cater for requirements within the performance range of the type of pump concerned.
All pumps are available as fitted pumps.
The pumps are maintenance-free, quiet, durable and vibration free. The diaphragms are made of high-grade material. They are the only wearing parts and are easy and quick to change on all models.
art. no
70 (…) ~ 160 l/h
power supply
AC
power consumption
4 Watt
dimensions with case
153 x 75 x 82 mm
weight with case
520 g
hose connection
5 mm Ø
Modifications:
power supply:
220-240 V/50 Hz
230 V/60 Hz
240 V/50 Hz
115-120 V/50 Hz
115-120 V/60 Hz
12 V/50 Hz
24 V/50 Hz
48 V/50 Hz
version:
without case/housing
with output connection
with in- and output connection
Vacuum version for this pump is not possible.
electrical connection:
1 m cable with European plug
1 m cable with US plug
1 m cable with UK plug
1 m cable without plug
0,5 m cable without plug
without cable
Further modifications regarding power supply, cable version etc. on inquiry.
Reserve technical changes.
Diagram
The curve shows the performance of the standard pump at the voltage stated.
art. no.
71 (…) ~ 250 l/h
power supply
AC
power consumption
5 Watt
dimensions with case
153 x 75 x 82 mm
weight with case
570 g
hose connection
5 mm Ø
Modifications:
power supply:
220-240 V/50 Hz
230 V/60 Hz
240 V/50 Hz
115-120 V/50 Hz
115-120 V/60 Hz
12 V/50 Hz
24 V/50 Hz
48 V/50 Hz
version:
without case/housing
with output connection
with in- and output connection
with input (vacuum) connection
electrical connection:
1 m cable with European plug
1 m cable with US plug
1 m cable with UK plug
1 m cable without plug
0,5 m cable without plug
without cable
Further modifications regarding power supply, cable version etc. on inquiry.
Reserve technical changes.
Diagram
The curve shows the performance of the standard pump at the voltage stated.
art. no.
73 (…) ~ 100 l/h
power supply
AC
power consumption
3 Watt
dimensions with case
116 x 66 x 51 mm
weight with case
350 g
hose connection
5 mm Ø
Modifications:
power supply:
220-240 V/50 Hz
230 V/60 Hz
240 V/50 Hz
115-120 V/50 Hz
115-120 V/60 Hz
12 V/50 Hz
24 V/50 Hz
48 V/50 Hz
version:
without case/housing
with output connection
with in- and output connection
with input (vacuum) connection
electrical connection:
1 m cable with European plug
1 m cable with US plug
1 m cable with UK plug
1 m cable without plug
0,5 m cable without plug
without cable
Further modifications regarding power supply, cable version etc. on inquiry.
Reserve technical changes.
Diagram
The curve shows the performance of the standard pump at the voltage stated.
art. no.
77 (…) ~ 150 l/h
power supply
AC
power consumption
5 Watt
dimensions with case
130 x 70 x 50 mm
weight with case
500 g
hose connection
5 mm Ø
Modifications:
power supply:
220-240 V/50 Hz
230 V/60 Hz
240 V/50 Hz
115-120 V/50 Hz
115-120 V/60 Hz
12 V/50 Hz
24 V/50 Hz
48 V/50 Hz
version:
without case/housing
with output connection
with in- and output connection
with input (vacuum) connection
electrical connection:
1 m cable with European plug
1 m cable with US plug
1 m cable with UK plug
1 m cable without plug
0,5 m cable without plug
without cable
Further modifications regarding power supply, cable version etc. on inquiry.
Reserve technical changes.
Diagram
The curve shows the performance of the standard pump at the voltage stated.
art. no.
85 (…) ~ 250 l/h
power supply
AC
power consumption
5 Watt
dimensions with case
130 x 70 x 50 mm
weight with case
550 g
hose connection
5 mm Ø
Modifications:
power supply:
220-240 V/50 Hz
230 V/60 Hz
240 V/50 Hz
115-120 V/50 Hz
115-120 V/60 Hz
12 V/50 Hz
24 V/50 Hz
48 V/50 Hz
version:
without case/housing
with output connection
with in- and output connection
with input (vacuum) connection
electrical connection:
1 m cable with European plug
1 m cable with US plug
1 m cable with UK plug
1 m cable without plug
0,5 m cable without plug
without cable
Further modifications regarding power supply, cable version etc. on inquiry.
Reserve technical changes.
Diagram
The curve shows the performance of the standard pump at the voltage stated.
art. no.
74 (…) ~ 350 l/h
power supply
AC
power consumption
5 Watt
dimensions with case
170 x 75 x 60 mm
weight with case
880 g
hose connection
5 mm Ø
Modifications:
power supply:
220-240 V/50 Hz
230 V/60 Hz
240 V/50 Hz
115-120 V/50 Hz
115-120 V/60 Hz
12 V/50 Hz
24 V/50 Hz
48 V/50 Hz
version:
without case/housing
with output connection
with in- and output connection
with input (vacuum) connection
electrical connection:
1 m cable with European plug
1 m cable with US plug
1 m cable with UK plug
1 m cable without plug
0,5 m cable without plug
without cable
Further modifications regarding power supply, cable version etc. on inquiry.
Reserve technical changes.
Diagram
The curve shows the performance of the standard pump at the voltage stated.
art. no.
92 (…) ~ 250 l/h
power supply
AC
power consumption
5 Watt
dimensions with case
130 x 70 x 50 mm
weight with case
550 g
hose connection
5 mm Ø
Modifications:
power supply:
220-240 V/50 Hz
230 V/60 Hz
240 V/50 Hz
115-120 V/50 Hz
115-120 V/60 Hz
12 V/50 Hz
24 V/50 Hz
48 V/50 Hz
version:
without case/housing
with output connection
with in- and output connection
with input (vacuum) connection
electrical connection:
1 m cable with European plug
1 m cable with US plug
1 m cable with UK plug
1 m cable without plug
0,5 m cable without plug
without cable
Further modifications regarding power supply, cable version etc. on inquiry.
Reserve technical changes.
Diagram
The curve shows the performance of the standard pump at the voltage stated.
art. no.
93 (…) ~ 350 l/h
power supply
AC
power consumption
7 Watt
dimensions with case
170 x 75 x 60 mm
weight with case
880 g
hose connection
5 mm Ø
Modifications:
power supply:
220-240 V/50 Hz
230 V/60 Hz
240 V/50 Hz
115-120 V/50 Hz
115-120 V/60 Hz
12 V/50 Hz
24 V/50 Hz
48 V/50 Hz
version:
without case/housing
with output connection
with in- and output connection
with input (vacuum) connection
electrical connection:
1 m cable with European plug
1 m cable with US plug
1 m cable with UK plug
1 m cable without plug
0,5 m cable without plug
without cable
Further modifications regarding power supply, cable version etc. on inquiry.
Reserve technical changes.
Diagram
The curve shows the performance of the standard pump at the voltage stated.
art. no
83 (….) ~ 180 l/h
power supply
DC
power consumption
400 mA
dimensions with case
130 x 70 x 50 mm
weight with case
550 g
hose connection
5 mm Ø
Modifications:
power supply:
12 V DC
24 V DC
version:
without case
with output connection
with in- and output connection
with input (vacuum) connection
electrical connection:
1 m cable without plug
0,5 m cable without plug
without plug
Further modifications regarding power supply, cable version etc. on inquiry.
Reserve technical changes.
Diagram
The curve shows the performance of the standard pump at the voltage stated.
art. no
82 (….) ~ 200 l/h
power supply
DC
power consumption
380 mA
dimensions with case
153 x 75 x 82 mm
weight with case
570 g
hose connection
5 mm Ø
Modifications:
power supply:
12 V DC
24 V DC
version:
without case
with output connection
with in- and output connection
with input (vacuum) connection
electrical connection:
1 m cable without plug
0,5 m cable without plug
without plug
Further modifications regarding power supply, cable version etc. on inquiry.
Reserve technical changes.
Diagram
The curve shows the performance of the standard pump at the voltage stated.
art. no
80 (….) ~ 280 l/h
power supply
DC
power consumption
600 mA
dimensions with case
170 x 75 x 60 mm
weight with case
880 g
hose connection
5 mm Ø
Modifications:
power supply:
12 V DC
24 V DC
version:
without case
with output connection
with in- and output connection
with input (vacuum) connection
electrical connection:
1 m cable without plug
0,5 m cable without plug
without plug
Further modifications regarding power supply, cable version etc. on inquiry.
Reserve technical changes.
Diagram
The curve shows the performance of the standard pump at the voltage stated.
art. no.
610
length
10 m
diameter
Ø 4/6 mm
art. no.
640
length
100 m
diameter
Ø 4/6 mm
art. no.
645
length
1 m
diameter
Ø 4/7 mm
art. no.
646
length
50 m
diameter
Ø 4/7 mm
Further hose accessories (reducing adapters, distributor pieces, brass outflow nozzles …) on request.
art. no
70 (…) ~ 160 l/h
power supply
AC
power consumption
4 Watt
dimensions with case
153 x 75 x 82 mm
weight with case
520 g
hose connection
5 mm Ø
Modifications:
power supply:
220-240 V/50 Hz
230 V/60 Hz
240 V/50 Hz
115-120 V/50 Hz
115-120 V/60 Hz
12 V/50 Hz
24 V/50 Hz
48 V/50 Hz
version:
without case/housing
with output connection
with in- and output connection
Vacuum version for this pump is not possible.
electrical connection:
1 m cable with European plug
1 m cable with US plug
1 m cable with UK plug
1 m cable without plug
0,5 m cable without plug
without cable
Further modifications regarding power supply, cable version etc. on inquiry.
Reserve technical changes.
Diagram
The curve shows the performance of the standard pump at the voltage stated.
art. no.
71 (…) ~ 250 l/h
power supply
AC
power consumption
5 Watt
dimensions with case
153 x 75 x 82 mm
weight with case
570 g
hose connection
5 mm Ø
Modifications:
power supply:
220-240 V/50 Hz
230 V/60 Hz
240 V/50 Hz
115-120 V/50 Hz
115-120 V/60 Hz
12 V/50 Hz
24 V/50 Hz
48 V/50 Hz
version:
without case/housing
with output connection
with in- and output connection
with input (vacuum) connection
electrical connection:
1 m cable with European plug
1 m cable with US plug
1 m cable with UK plug
1 m cable without plug
0,5 m cable without plug
without cable
Further modifications regarding power supply, cable version etc. on inquiry.
Reserve technical changes.
Diagram
The curve shows the performance of the standard pump at the voltage stated.
art. no.
73 (…) ~ 100 l/h
power supply
AC
power consumption
3 Watt
dimensions with case
116 x 66 x 51 mm
weight with case
350 g
hose connection
5 mm Ø
Modifications:
power supply:
220-240 V/50 Hz
230 V/60 Hz
240 V/50 Hz
115-120 V/50 Hz
115-120 V/60 Hz
12 V/50 Hz
24 V/50 Hz
48 V/50 Hz
version:
without case/housing
with output connection
with in- and output connection
with input (vacuum) connection
electrical connection:
1 m cable with European plug
1 m cable with US plug
1 m cable with UK plug
1 m cable without plug
0,5 m cable without plug
without cable
Further modifications regarding power supply, cable version etc. on inquiry.
Reserve technical changes.
Diagram
The curve shows the performance of the standard pump at the voltage stated.
art. no.
77 (…) ~ 150 l/h
power supply
AC
power consumption
5 Watt
dimensions with case
130 x 70 x 50 mm
weight with case
500 g
hose connection
5 mm Ø
Modifications:
power supply:
220-240 V/50 Hz
230 V/60 Hz
240 V/50 Hz
115-120 V/50 Hz
115-120 V/60 Hz
12 V/50 Hz
24 V/50 Hz
48 V/50 Hz
version:
without case/housing
with output connection
with in- and output connection
with input (vacuum) connection
electrical connection:
1 m cable with European plug
1 m cable with US plug
1 m cable with UK plug
1 m cable without plug
0,5 m cable without plug
without cable
Further modifications regarding power supply, cable version etc. on inquiry.
Reserve technical changes.
Diagram
The curve shows the performance of the standard pump at the voltage stated.
art. no.
85 (…) ~ 250 l/h
power supply
AC
power consumption
5 Watt
dimensions with case
130 x 70 x 50 mm
weight with case
550 g
hose connection
5 mm Ø
Modifications:
power supply:
220-240 V/50 Hz
230 V/60 Hz
240 V/50 Hz
115-120 V/50 Hz
115-120 V/60 Hz
12 V/50 Hz
24 V/50 Hz
48 V/50 Hz
version:
without case/housing
with output connection
with in- and output connection
with input (vacuum) connection
electrical connection:
1 m cable with European plug
1 m cable with US plug
1 m cable with UK plug
1 m cable without plug
0,5 m cable without plug
without cable
Further modifications regarding power supply, cable version etc. on inquiry.
Reserve technical changes.
Diagram
The curve shows the performance of the standard pump at the voltage stated.
art. no.
74 (…) ~ 350 l/h
power supply
AC
power consumption
5 Watt
dimensions with case
170 x 75 x 60 mm
weight with case
880 g
hose connection
5 mm Ø
Modifications:
power supply:
220-240 V/50 Hz
230 V/60 Hz
240 V/50 Hz
115-120 V/50 Hz
115-120 V/60 Hz
12 V/50 Hz
24 V/50 Hz
48 V/50 Hz
version:
without case/housing
with output connection
with in- and output connection
with input (vacuum) connection
electrical connection:
1 m cable with European plug
1 m cable with US plug
1 m cable with UK plug
1 m cable without plug
0,5 m cable without plug
without cable
Further modifications regarding power supply, cable version etc. on inquiry.
Reserve technical changes.
Diagram
The curve shows the performance of the standard pump at the voltage stated.
art. no.
92 (…) ~ 250 l/h
power supply
AC
power consumption
5 Watt
dimensions with case
130 x 70 x 50 mm
weight with case
550 g
hose connection
5 mm Ø
Modifications:
power supply:
220-240 V/50 Hz
230 V/60 Hz
240 V/50 Hz
115-120 V/50 Hz
115-120 V/60 Hz
12 V/50 Hz
24 V/50 Hz
48 V/50 Hz
version:
without case/housing
with output connection
with in- and output connection
with input (vacuum) connection
electrical connection:
1 m cable with European plug
1 m cable with US plug
1 m cable with UK plug
1 m cable without plug
0,5 m cable without plug
without cable
Further modifications regarding power supply, cable version etc. on inquiry.
Reserve technical changes.
Diagram
The curve shows the performance of the standard pump at the voltage stated.
art. no.
93 (…) ~ 350 l/h
power supply
AC
power consumption
7 Watt
dimensions with case
170 x 75 x 60 mm
weight with case
880 g
hose connection
5 mm Ø
Modifications:
power supply:
220-240 V/50 Hz
230 V/60 Hz
240 V/50 Hz
115-120 V/50 Hz
115-120 V/60 Hz
12 V/50 Hz
24 V/50 Hz
48 V/50 Hz
version:
without case/housing
with output connection
with in- and output connection
with input (vacuum) connection
electrical connection:
1 m cable with European plug
1 m cable with US plug
1 m cable with UK plug
1 m cable without plug
0,5 m cable without plug
without cable
Further modifications regarding power supply, cable version etc. on inquiry.
Reserve technical changes.
Diagram
The curve shows the performance of the standard pump at the voltage stated.
art. no
83 (….) ~ 180 l/h
power supply
DC
power consumption
400 mA
dimensions with case
130 x 70 x 50 mm
weight with case
550 g
hose connection
5 mm Ø
Modifications:
power supply:
12 V DC
24 V DC
version:
without case
with output connection
with in- and output connection
with input (vacuum) connection
electrical connection:
1 m cable without plug
0,5 m cable without plug
without plug
Further modifications regarding power supply, cable version etc. on inquiry.
Reserve technical changes.
Diagram
The curve shows the performance of the standard pump at the voltage stated.
art. no
82 (….) ~ 200 l/h
power supply
DC
power consumption
380 mA
dimensions with case
153 x 75 x 82 mm
weight with case
570 g
hose connection
5 mm Ø
Modifications:
power supply:
12 V DC
24 V DC
version:
without case
with output connection
with in- and output connection
with input (vacuum) connection
electrical connection:
1 m cable without plug
0,5 m cable without plug
without plug
Further modifications regarding power supply, cable version etc. on inquiry.
Reserve technical changes.
Diagram
The curve shows the performance of the standard pump at the voltage stated.
art. no
80 (….) ~ 280 l/h
power supply
DC
power consumption
600 mA
dimensions with case
170 x 75 x 60 mm
weight with case
880 g
hose connection
5 mm Ø
Modifications:
power supply:
12 V DC
24 V DC
version:
without case
with output connection
with in- and output connection
with input (vacuum) connection
electrical connection:
1 m cable without plug
0,5 m cable without plug
without plug
Further modifications regarding power supply, cable version etc. on inquiry.
Reserve technical changes.
Diagram
The curve shows the performance of the standard pump at the voltage stated.
art. no.
610
length
10 m
diameter
Ø 4/6 mm
art. no.
640
length
100 m
diameter
Ø 4/6 mm
art. no.
645
length
1 m
diameter
Ø 4/7 mm
art. no.
646
length
50 m
diameter
Ø 4/7 mm
Further hose accessories (reducing adapters, distributor pieces, brass outflow nozzles …) on request.
At SCHEGO® we do things differently: Reliable, approved and innovative high-quality products in connection with the special services of a family-run business characterize our company. Development, production and distribution – everything from a single source.
We guarantee best quality and prompt delivery not only for our standard products but also for our user-defined and purpose-built products for industrial applications. more…